Violation Detail
Standard Cited: 19100147 F03 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 957343.015
Citation: 01003
Citation Type: Other
Abatement Date: 11/18/2014 2
Initial Penalty: $7,000.00
Current Penalty: $4,900.00
Issuance Date: 07/25/2014
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC): A
Gravity:
Report ID: 0627510
Contest Date: 08/19/2014
Final Order: 11/07/2014
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 11/07/2014 | $4,900.00 | 11/18/2014 | Other | |
Penalty | C: Contested | 08/19/2014 | $7,000.00 | 08/06/2014 | Serious | |
Penalty | Z: Issued | 07/25/2014 | $7,000.00 | 08/06/2014 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.147(f)(3)(i): When maintenance was performed by a crew, craft, department or other group, a procedure was not utilized that afforded the employees a level of protection equivalent to that provided by the implementation of a personal lockout or tagout device: On or about January 29, 2014, Enbridge Pipelines did not utilize a procedure to lock out a section of pipeline that ensured all participants in a valve change were protected against hazardous energy.