Violation Detail
Standard Cited: 19260451 E01 General requirements.
Inspection Nr: 928065.015
Citation: 01003
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $1,200.00
Current Penalty: $720.00
Issuance Date: 08/21/2013
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 08/27/2013
Gravity: 1
Report ID: 0625400
Contest Date:
Final Order: 10/17/2013
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 10/17/2013 | $720.00 | 08/27/2013 | Serious | |
| Penalty | Z: Issued | 08/21/2013 | $1,200.00 | 08/27/2013 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Support legs were used as a means of access. On 12 August 2013, two workers were accessing the 1st tier of a tubular-welded frame scaffold to perform mason work without the use of a ladder, exposing the workers to a fall hazard of approximately 7.5 feet to the ground below.