Violation Detail
Standard Cited: 19100023 A09 Ladders.
Inspection Nr: 92216.015
Citation: 01003
Citation Type: Serious
Abatement Date: 01/05/2012 2
Initial Penalty: $4,675.00
Current Penalty: $2,805.00
Issuance Date: 12/21/2011
Nr Instances: 1
Nr Exposed: 6
Related Event Code (REC):
Gravity: 5
Report ID: 0830500
Contest Date:
Final Order: 01/13/2012
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 01/13/2012 | $2,805.00 | 01/05/2012 | Serious | |
Penalty | Z: Issued | 12/21/2011 | $4,675.00 | 01/05/2012 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.23 (a)(9): The employer did not guard the floor holes into which persons cannot accidentially walk (on account of fixed machinery, equipment, or walls) shall be protected by a cover that leaves no openings more than 1 inch wide. The cover shall be securlely held in place to prevent tools or materials from falling through: (a) Cyclone Drilling, Inc., Drilling Rig 17, API 05-045-19478, Rifle, CO 81650: On and before July 7, 2011 the creating, exposing and correcting employer did not guard six circular openings of approximately 9'' diameter on the mud tank floor. These hole openings have 14'' rods sticking out of them as well. This condition exposed employees to slip, trip, and fall hazards. Abatement Note: Abatement certification and documentation are required for this item (see enclose Corrective Action Worksheet).