Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 907383.015
Citation: 01003
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $7,000.00
Current Penalty: $4,200.00
Issuance Date: 08/27/2013
Nr Instances: 1
Nr Exposed: 3
Abatement Date:
Gravity: 10
Report ID: 0418300
Contest Date:
Final Order: 09/20/2013
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 09/20/2013 | $4,200.00 | Serious | ||
| Penalty | Z: Issued | 08/27/2013 | $7,000.00 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) On or about May 15, 2013 - Dado department, specific procedures had not been established for employees performing maintenance on equipment such as, but not limited to, the Selco WN600 panel saw, Selco WN200, KL310 edge bander, SE9500 edge bander, #1 & #2 Biesse router, base hole drill, wall hole drill, #1,#2, and #3 CTD end panel notcher.