Violation Detail
Standard Cited: 19100134 I07 Respiratory Protection.
Inspection Nr: 891351.015
Citation: 01003
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $4,900.00
Current Penalty: $2,940.00
Issuance Date: 05/03/2013
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 06/07/2013
Gravity: 10
Report ID: 0418300
Contest Date:
Final Order: 06/04/2013
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/04/2013 | $2,940.00 | 06/07/2013 | Serious | |
| Penalty | Z: Issued | 05/03/2013 | $4,900.00 | 06/07/2013 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.134(i)(7): Oil lubricated compressor(s) used to supply breathing air did not have a high-temperature or carbon monoxide alarm(s) or both: (a) On or about March 6, 2013 - Abrasive blasting area, an oil-lubricated compressor used to supply the breathing air for the airline respirators was not provided with a high temperature or carbon monoxide alarm, or both, to monitor levels of carbon monoxide.