Violation Detail
Standard Cited: 19260451 E01 General requirements.
Inspection Nr: 435911.015
Citation: 01003
Citation Type: Serious
Abatement Status: Not Completed - Worksite Changed
Initial Penalty: $2,000.00
Current Penalty: $2,000.00
Issuance Date: 10/04/2012
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 10/10/2012
Gravity: 5
Report ID: 0214700
Contest Date:
Final Order: 10/30/2012
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 10/04/2012 | $2,000.00 | 10/10/2012 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access: a) Worksite, south side of building - Employee was climbing the frames of a fabricated frame scaffold to gain access to the third tier, approximately 18 feet above the ground level; on or about 05/18/2012. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.