Standard Cited: 19100119 D03 I B Process safety management of highly hazardous chemicals.

Inspection Nr: 432035.015

Citation: 01003

Citation Type: Serious

Abatement Status: Abatement Completed

Initial Penalty: $4,250.00

Current Penalty: $4,250.00

Issuance Date: 10/05/2012

Nr Instances: 7

Nr Exposed: 7

Abatement Date: 07/01/2013

Gravity: 5

Report ID: 0830600

Contest Date:

Final Order: 10/24/2012

Related Event Code (REC):

Emphasis:


Penalty and Failure to Abate Event History
Type Latest Event Event Date Penalty Abatement Due Date Citation Type Failure to Abate Inspection
Penalty I: Informal Settlement 10/24/2012 $4,250.00 07/01/2013 Serious  
Penalty Z: Issued 10/05/2012 $4,250.00 12/12/2012 Serious  

Text For Citation: 01 Item/Group: 003 Hazard:

29 CFR 1910.119(d)(3)(i)(B): Information pertaining to the equipment in the process did not include accurate piping and instrument diagrams (P&ID's): a) On or about May 14, 2012 and times prior, the employer's piping and instrument diagrams (P&ID's) were not accurate and did not reflect equipment that was existing in the actual process including, but not limited to, the following: 1. P&ID FS-105A showed a valve upstream of PSV 511A where there was no actual valve in the process. 2. P&ID FS-105A did not show two (2) drain valves and two (2) flanges on the waste gas stream line which are in place in the actual process. 3. P&ID FS-106 showed two (2) 4 inch valves on an inlet line and discharge line to S-101 in the "locked open" position where these were operational valves and were not locked open in the actual process. 4. P&ID FS-106 did not show a second ball valve and piping connected to a 3/4 inch gate valve on the NGL discharge line upstream of FE-615 that was in place in the actual process. 5. P&ID FS-106A showed a PSV 639 when the PSV was labeled as PSV 646 in the actual process. 6. P&ID FS-110 showed F-102 with a discharge line going from PSV 1039 venting to atmosphere where the actual process had the discharge line going from PSV 1039 to a "rich amine line" and not to atmosphere. 7. The symbol for pressure safety valve in the P&ID legend did not accurately reflect the symbol for PSV used throughouth all the P&IDs. The symbol for a regular angle valve was used in many cases as the symbol for a PSV. Abatement Note: Abatement certification and documentation is required for this item (see enclosed "Certification of Corrective Action Worksheet").

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close