Violation Detail
Standard Cited: 19100219 E03 I Mechanical power-transmission apparatus.
Inspection Nr: 403702.015
Citation: 01003
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $5,000.00
Current Penalty: $2,500.00
Issuance Date: 09/12/2012
Nr Instances: 4
Nr Exposed: 10
Abatement Date: 09/26/2012
Gravity: 5
Report ID: 0214700
Contest Date:
Final Order: 10/04/2012
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 10/04/2012 | $2,500.00 | 09/26/2012 | Serious | |
| Penalty | Z: Issued | 09/12/2012 | $5,000.00 | 09/26/2012 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o) a) West side, Sealer Department, L-Sealer Machines #1, #2, #3, #4 off the aisle, did not have pulley guards on an approximately 3" diameter pulley, driven by 1/2" belt, located approximately 35" off the flloor. Employee caught his finger in the in-going nip point of machine #2; On or about 04/25/12. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.