Powered by GoogleTranslate

Violation Detail

Standard Cited: 19100219 E03 I Mechanical power-transmission apparatus.

Inspection Nr: 403702.015

Citation: 01003

Citation Type: Serious

Abatement Status: Abatement Completed

Initial Penalty: $5,000.00

Current Penalty: $2,500.00

Issuance Date: 09/12/2012

Nr Instances: 4

Nr Exposed: 10

Abatement Date: 09/26/2012

Gravity: 5

Report ID: 0214700

Contest Date:

Final Order: 10/04/2012

Related Event Code (REC):

Emphasis:


Penalty and Failure to Abate Event History
Type Latest Event Event Date Penalty Abatement Due Date Citation Type Failure to Abate Inspection
Penalty I: Informal Settlement 10/04/2012 $2,500.00 09/26/2012 Serious  
Penalty Z: Issued 09/12/2012 $5,000.00 09/26/2012 Serious  

Text For Citation: 01 Item/Group: 003 Hazard:

29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o) a) West side, Sealer Department, L-Sealer Machines #1, #2, #3, #4 off the aisle, did not have pulley guards on an approximately 3" diameter pulley, driven by 1/2" belt, located approximately 35" off the flloor. Employee caught his finger in the in-going nip point of machine #2; On or about 04/25/12. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close