Violation Detail
Standard Cited: 19261053 B01 Ladders.
Inspection Nr: 1890965.015
Citation: 01003
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $2,838.00
Current Penalty: $2,838.00
Issuance Date: 05/28/2026
Nr Instances: 1
Nr Exposed: 3
Abatement Date:
Gravity: 5
Report ID: 0830300
Contest Date:
Final Order: 06/30/2026
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 05/28/2026 | $2,838.00 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: (a) On April 28, 2026 at or near 2716 Second Avenue West in Williston, North Dakota, employees using an aluminum extension ladder to access and egress the roof deck were exposed to injuries from the displacement of an improperly installed ladder.