Violation Detail
Standard Cited: 19100179 N02 II Overhead and gantry cranes.
Inspection Nr: 1820974.015
Citation: 01003
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $16,550.00
Current Penalty: $16,550.00
Issuance Date: 10/17/2025
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 11/13/2025
Gravity: 10
Report ID: 0213900
Contest Date: 11/13/2025
Final Order: 02/27/2026
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | J: ALJ Decision | 02/27/2026 | $16,550.00 | 11/13/2025 | Serious | |
| Penalty | C: Contested | 11/13/2025 | $16,550.00 | 11/13/2025 | Serious | |
| Penalty | Z: Issued | 10/17/2025 | $16,550.00 | 11/13/2025 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.179(n)(2)(ii):The load was not attached to the load block hook by means of slings or other approved devices: a)418 Southgate Court, Mickleton, NJ 08056 Garage: A tie down strap with a rated load capacity of 3,333 pounds was used to suspend the boom on the Magni Telescopic Handler, Model TH 5,5.19-D7/D that weighed 8,010 pounds while performing repairs, on or about 4/28/25. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.