Violation Detail
Standard Cited: 19100219 F01 I Mechanical power-transmission apparatus.
This violation item has been deleted.
Inspection Nr: 1800955.015
Citation: 01003
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $16,550.00
Current Penalty: $0.00
Issuance Date: 04/18/2025
Nr Instances: 1
Nr Exposed: 12
Abatement Date:
Gravity: 10
Report ID: 0522000
Contest Date:
Final Order: 04/30/2025
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/30/2025 | $0.00 | Serious | ||
Penalty | Z: Issued | 04/18/2025 | $16,550.00 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.219(f)(1): Gears. Gears shall be guarded in accordance with one of the following methods: (i): By a complete enclosure; or a) On or before January 22, 2025, the employer did not ensure that the gears on the FBT1 Furnace, located in the Coating Plant, were enclosed as required. The gears were located less than seven (7) feet above the floor and were not provided with adequate guarding, exposing employees to contact with the moving components. As a result, employees were exposed to caught-in hazards from the unguarded moving gear components.