Violation Detail
Standard Cited: 19100147 C06 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1799395.015
Citation: 01003
Citation Type: Serious
Abatement Status:
Initial Penalty: $16,550.00
Current Penalty: $16,550.00
Issuance Date: 07/11/2025
Nr Instances: 1
Nr Exposed: 7
Abatement Date: 08/07/2025
Gravity: 10
Report ID: 0214200
Contest Date: 08/07/2025
Final Order:
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | C: Contested | 08/08/2025 | $16,550.00 | 08/07/2025 | Serious | |
| Penalty | Z: Issued | 07/11/2025 | $16,550.00 | 08/07/2025 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.147(c)(6):The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed: a) 1 Eastern Rd, Kearny NJ The employer did not conduct annual inspections of energy control procedures for industrial laundry equipment including but not limited to Dryer #4 "Power Dry" and "Ironer line 1." Violation occurred on or about January 18, 2025