Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1797596.015
Citation: 01003
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $16,550.00
Current Penalty: $9,930.00
Issuance Date: 05/23/2025
Nr Instances: 1
Nr Exposed: 3
Abatement Date:
Gravity: 10
Report ID: 0522300
Contest Date:
Final Order: 06/25/2025
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 06/25/2025 | $9,930.00 | Serious | ||
Penalty | Z: Issued | 05/23/2025 | $16,550.00 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.219(d)(1):Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): On or about January 14, 2025, the employer did not ensure guarding of a pulley belt system for employees working in close proximity while performing cleaning procedures on the Asitrade 1, 1994.960, MPC-III, Bobst G07 Module Facer MF 260, Starch Roller Unit located in the lamination department.