Violation Detail
Standard Cited: 19260451 C01 III General requirements.
This violation item has been deleted.
Inspection Nr: 1789975.015
Citation: 01003
Citation Type: Serious
Abatement Status:
Initial Penalty: $11,585.00
Current Penalty: $0.00
Issuance Date: 05/01/2025
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 05/28/2025
Gravity: 10
Report ID: 0626700
Contest Date:
Final Order: 06/02/2025
Related Event Code (REC): A
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 06/02/2025 | $0.00 | 05/28/2025 | Serious | |
Penalty | Z: Issued | 05/01/2025 | $11,585.00 | 05/28/2025 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1926.451(c)(1)(iii): Ties, guys, braces, or outriggers shall be used to prevent the tipping of supported scaffolds in all circumstances where an eccentric load, such as a cantilevered work platform, is applied or is transmitted to the scaffold. (a) On or about November 21, 2024, at the jobsite, where employee(s) was using a winch, attached to the scaffold by a hoisting arm on the corner of the scaffold, to lift a concrete wall panel without ties, guys, braces or outriggers.