Violation Detail
Standard Cited: 19100179 L03 I Overhead and gantry cranes.
Inspection Nr: 1781116.015
Citation: 01003
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $16,131.00
Current Penalty: $12,098.00
Issuance Date: 11/29/2024
Nr Instances: 3
Nr Exposed: 20
Abatement Date: 12/16/2024
Gravity: 10
Report ID: 0524700
Contest Date:
Final Order: 12/16/2024
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 12/16/2024 | $12,098.00 | 12/16/2024 | Serious | |
Penalty | Z: Issued | 11/29/2024 | $16,131.00 | 12/06/2024 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.179(l)(3)(i): Unsafe condition(s) disclosed during the frequent or periodic inspection(s) required by 29 CFR 1910.179(j) were not corrected before operation of the crane(s) was resumed. a. ABC Technologies WMG USA, Inc. - Bellevue, Ohio: On or about September 30, 2024, the employer did not ensure that unsafe conditions identified during the annual inspections of Crane #1, a floor-operated Shepard Niles overhead gantry crane (s/n 70260B), were corrected prior to continued use. Inspections disclosed that the bridge and trolley lacked rail sweeps to prevent damage to wheels and derailment. Employees who operated the crane to move machine molds were exposed to struck-by and crushing injuries. b. ABC Technologies WMG USA, Inc. - Bellevue, Ohio: On or about September 30, 2024, the employer did not ensure that unsafe conditions identified during the annual inspection of Crane #2, a floor-operated Engineered Material Handling overhead gantry crane (model ZLK; s/n 975382) were corrected prior to continued use. Inspections disclosed that the radio-controlled pendant was missing function labels, and the wire rope dead end required redress to prevent slippage. Employees who operated the crane to move machine molds were exposed to struck-by and crushing injuries. c. ABC Technologies WMG USA, Inc. - Bellevue, Ohio: On or about September 30, 2024, the employer did not ensure that unsafe conditions identified during the annual inspections of Crane #4, a floor-operated Engineered Material Handling overhead gantry crane (s/n 102016) were corrected prior to continued use. Inspections disclosed that the wire rope was incorrectly installed in the wedge socket. Employees who operated the crane to move machine molds were exposed to struck-by and crushing injuries. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.