Violation Detail
Standard Cited: 19100212 A03 II General requirements for all machines.
Inspection Nr: 1769454.015
Citation: 01003
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $16,131.00
Current Penalty: $12,098.00
Issuance Date: 09/27/2024
Nr Instances: 1
Nr Exposed: 5
Abatement Date: 11/01/2024
Gravity: 10
Report ID: 0522300
Contest Date:
Final Order: 10/24/2024
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/24/2024 | $12,098.00 | 11/01/2024 | Serious | |
Penalty | Z: Issued | 09/27/2024 | $16,131.00 | 11/01/2024 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): AVD amended to, ?On or about August 8, 2024, the point of operation guarding on the Minster Mechanical Power Press (Model 3, Herion 2493020, Serial #35/38) permitted employees to bypass the guard and come into contact with the ram of the press at the point of the operation where the inserted part was being crimped.