Violation Detail
Standard Cited: 19260652 A01 Requirements for protective systems.
This violation item has been deleted.
Inspection Nr: 1765116.015
Citation: 01003
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $16,550.00
Current Penalty: $0.00
Issuance Date: 01/24/2025
Nr Instances: 1
Nr Exposed: 1
Abatement Date:
Gravity: 10
Report ID: 0317300
Contest Date:
Final Order: 04/10/2025
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/10/2025 | $0.00 | Serious | ||
Penalty | Z: Issued | 01/24/2025 | $16,550.00 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c): a) Phase 6 of the Chase Oaks Development, Lewes, DE - On or about 07/29/2024, employee was exposed to cave-ins and/or struck by hazards while working without protective systems. The trench was measured at approximately 6 ft. in depth, 5 ft. in width.