Violation Detail
Standard Cited: 19100219 C02 I Mechanical power-transmission apparatus.
Inspection Nr: 1759894.015
Citation: 01003
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $25,353.00
Current Penalty: $10,141.00
Issuance Date: 12/09/2024
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 12/31/2024
Gravity: 5
Report ID: 0627700
Contest Date:
Final Order: 02/13/2025
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 02/13/2025 | $10,141.00 | 12/31/2024 | Serious | |
Penalty | Z: Issued | 12/09/2024 | $25,353.00 | 12/31/2024 | Repeat |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: On or about June 25, 2024, in the Tube Cell Fabrication area, a form roller machine had a rotating horizontal shaft that was less than 7 feet from the floor with no enclosure or trough to protect employees from contacting the rotating shaft. The ACME Engineering & Manufacturing Corp was previously cited for a violation of this Occupational Safety and Health standard or its equivalent standard 29 CFR 1910.219 (c) (2) (i), which was contained in OSHA inspection number 1650517, citation number 1, item number 1b and was affirmed as a final order on August 21, 2023, with respect to a workplace located at 1820 N. York St., Muskogee, OK 74403.