Violation Detail
Standard Cited: 19260451 G01 VII General requirements.
Inspection Nr: 1753162.015
Citation: 01003
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $4,839.00
Current Penalty: $3,750.00
Issuance Date: 12/04/2024
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 12/12/2024
Gravity: 10
Report ID: 0215600
Contest Date:
Final Order: 01/09/2025
Related Event Code (REC): A
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 01/09/2025 | $3,750.00 | 12/12/2024 | Serious | |
Penalty | Z: Issued | 12/04/2024 | $4,839.00 | 12/12/2024 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: a) On or about 06/05/24, at 38-29 30th Street. Long Island City, NY south side of the property. Employees installing siding from the fabricated frame scaffold were exposed fall hazards of approximately 18-ft to the ground. Guardrails or personal fall arrest systems were not used.