Violation Detail
Standard Cited: 19100147 C04 II C The control of hazardous energy (lockout/tagout).
Inspection Nr: 1745308.015
Citation: 01003
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $11,292.00
Current Penalty: $7,700.00
Issuance Date: 05/29/2024
Nr Instances: 2
Nr Exposed: 3
Abatement Date: 06/25/2024
Gravity: 10
Report ID: 0317700
Contest Date:
Final Order: 06/19/2024
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/19/2024 | $7,700.00 | 06/25/2024 | Serious | |
| Penalty | Z: Issued | 05/29/2024 | $11,292.00 | 06/25/2024 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.147(c)(4)(ii)(C): The energy control procedure did not clearly and specifically outline the steps for placement, removal and transfer of lockout devices or tagout devices and the responsibility for them: a) Chipper - On or about May 1, 2024, employees performing maintenance were exposed to amputation hazards from an energy control procedure for the Chipper machine that did not clearly outline the steps for placement and removal of lockout or tagout devices. b) Optimizing Edger - On or about May 1, 2024, employees performing maintenance were exposed to amputation hazards from an energy control procedure for the Optimizing Edger that did not clearly outline the steps for placement and removal of lockout or tagout devices. ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED