Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1742742.015
Citation: 01003
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $11,524.00
Current Penalty: $0.00
Issuance Date: 08/02/2024
Nr Instances: 11
Nr Exposed: 100
Abatement Date: 08/30/2024
Gravity: 5
Report ID: 0521100
Contest Date:
Final Order: 08/27/2024
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/27/2024 | $0.00 | 08/30/2024 | Serious | |
Penalty | Z: Issued | 08/02/2024 | $11,524.00 | 08/30/2024 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed. At an establishment located at N2915 County Road AB in Luxemburg, Wisconsin: a) On or about April 22, 2024, the employer did not conduct periodic inspections of their energy control procedures at least annually to ensure that the procedures and the requirements of the standard were followed on the RH Cryovac, Cooker #1, RMC #1 carousel, RMC #1 molder, RMC #2 carousel, RMC #2 molder, Milk Minerals Dryer (MMD), and Permeate Dryer to ensure employees were protected from potential entanglement, amputation, asphyxiation, and fire hazards by performing a periodic inspection to performing cleaning activities in the machines.