Violation Detail
Standard Cited: 19150051 B01 IV Ventilation and protection in welding, cutting and heating.
Inspection Nr: 1722934.015
Citation: 01003
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $16,131.00
Current Penalty: $12,904.80
Issuance Date: 07/19/2024
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 09/03/2024
Gravity: 10
Report ID: 0625700
Contest Date:
Final Order: 09/03/2024
Related Event Code (REC): A
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 09/03/2024 | $12,904.80 | 09/03/2024 | Serious | |
Penalty | Z: Issued | 07/19/2024 | $16,131.00 | 08/14/2024 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
1915.51(b)(1)(iv): Contaminated air, exhausted from a working space, was not discharged into the open air or otherwise clear of the source of intake air. a) On or about January 22, 2024, the site supervisor did not verify that the ventilation ductwork that had been set up by an employee performing welding work in a confined space was set up properly to maintain a safe atmosphere.