Violation Detail
Standard Cited: 19100212 A01 General requirements for all machines.
Inspection Nr: 1715329.015
Citation: 01003
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $11,524.00
Current Penalty: $1,000.00
Issuance Date: 05/08/2024
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 09/16/2024
Gravity: 5
Report ID: 0521400
Contest Date:
Final Order: 06/03/2024
Related Event Code (REC): C
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/03/2024 | $1,000.00 | 09/16/2024 | Other | |
| Penalty | Z: Issued | 05/08/2024 | $11,524.00 | 06/14/2024 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. GenSet Building, Laser 2: On or about December 8, 2023, employees were exposed to amputation, pinching and struck by hazards, due to the table movement, while removing metal scrap from the BySprint Fiber 4020 shuttle table system and while transferring the metal sheet to the BySprint Fiber 4020 shuttle table system. An existing light curtain, used as machine guarding, is not effective because employees can position themselves between the light curtain and the table. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).