Violation Detail
Standard Cited: 19260502 D06 I Fall protection systems criteria and practices.
Inspection Nr: 1712315.015
Citation: 01003
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $4,610.00
Current Penalty: $4,610.00
Issuance Date: 05/15/2024
Nr Instances: 1
Nr Exposed: 10
Related Event Code (REC):
Gravity: 5
Report ID: 0213600
Contest Date:
Final Order: 06/10/2024
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 05/15/2024 | $4,610.00 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1926.502(d)(6)(i): Snaphooks were engaged directly to webbing, rope or wire rope; a) On or about 11/23/2023 at the southeast side of the building; employees were replacing the roof of a repurposed church building. Employees were using a personal fall arrest system with the snaphook end of a vertical lifeline rope wrapped around a rafter, then connected back to the lanyard rope. The snaphook was not designed for use in this application and could become disengaged in a fall. Employees were exposed to a fall of approximately 50 feet. NO ABATEMENT CERTIFICATION REQUIRED