Violation Detail
Standard Cited: 19100179 N04 I Overhead and gantry cranes.
Inspection Nr: 1709469.015
Citation: 01003
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $16,131.00
Current Penalty: $16,131.00
Issuance Date: 05/02/2024
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 05/29/2024
Gravity: 10
Report ID: 0627700
Contest Date:
Final Order: 05/30/2024
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/30/2024 | $16,131.00 | 05/29/2024 | Serious | |
Penalty | Z: Issued | 05/02/2024 | $16,131.00 | 05/29/2024 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.179(n)(4)(i): The upper limit switch of each hoist was not tried out under no load, at the beginning of each operator's shift. a. On or about November 3, 2023, at a kettle of molten zinc, an overhead crane limit switch was not tried out under no load before use at the start of the operator's shift. An employee used the crane to move parts to and from the kettle of molten zinc. This exposed to struck-by hazards. b. On or about November 3, 2023, kettle area, an overhead crane's limit switch cover was identified 9/17/2023 as being damaged and was not replaced until 11/11/2023. This exposed employees to struck-by hazards.