Violation Detail
Standard Cited: 19261053 B01 Ladders.
Inspection Nr: 1700162.015
Citation: 01003
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $3,349.00
Current Penalty: $3,349.00
Issuance Date: 10/12/2023
Nr Instances: 1
Nr Exposed: 1
Abatement Date:
Gravity: 5
Report ID: 0626600
Contest Date:
Final Order: 02/14/2024
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 10/12/2023 | $3,349.00 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed. On or about September 28, 2023, employees were exposed to a fall hazard while accessing the roof with a ladder that did not extend at least 3 feet above the upper landing surface being accessed.
Translate