Standard Cited: 19100147 C07 I A The control of hazardous energy (lockout/tagout).
Inspection Nr: 1685470.015
Citation: 01003
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $10,938.00
Current Penalty: $4,375.00
Issuance Date: 09/29/2023
Nr Instances: 1
Nr Exposed: 20
Abatement Date: 01/17/2024
Gravity: 10
Report ID: 0522300
Contest Date: 10/25/2023
Final Order: 01/25/2024
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 01/25/2024 | $4,375.00 | 01/17/2024 | Serious | |
Penalty | C: Contested | 10/25/2023 | $10,938.00 | 11/17/2023 | Serious | |
Penalty | Z: Issued | 09/29/2023 | $10,938.00 | 11/17/2023 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.147(c)(7)(i)(A):Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation: On or about July 24, 2023, the employer did not ensure that employees tasked with the service and maintenance of equipment within the facility had received training as authorized personnel for the control of hazardous energies. Employees are tasked with service and maintenance including setup on equipment including but not limited to shavers, headers, horizontal drilling machines, and tapping machine. Hazardous energies present on equipment include but are not limited to mechanical, electrical, pneumatic, and hydraulic.