Violation Detail
Standard Cited: 19100147 C07 III A The control of hazardous energy (lockout/tagout).
Inspection Nr: 1658586.015
Citation: 01003
Citation Type: Other
Abatement Status: Corrected During Inspection
Initial Penalty: $14,063.00
Current Penalty: $7,031.00
Issuance Date: 09/20/2023
Nr Instances: 1
Nr Exposed: 6
Abatement Date:
Gravity: 10
Report ID: 0214500
Contest Date: 10/16/2023
Final Order: 05/17/2024
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 05/17/2024 | $7,031.00 | Other | ||
Penalty | C: Contested | 10/24/2023 | $14,063.00 | Serious | ||
Penalty | Z: Issued | 09/20/2023 | $14,063.00 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.147(c)(7)(iii)(A): Retraining was not provided for authorized and affected employees when there was a change in their job assignments, a change in machines, equipment or processes that presented a new hazard, or when there was a change in the energy control procedures: a) Catbridge Coater / Laminator (Coater #5) Serial Number PL55766: The employer did not retrain authorized and affected employees when there was a change in machine, on or about 3/23/23.