Standard Cited: 19100119 D03 II Process safety management of highly hazardous chemicals.

Inspection Nr: 1657906.015

Citation: 01003

Citation Type: Serious

Abatement Status: Abatement Completed

Initial Penalty: $15,625.00

Current Penalty: $11,000.00

Issuance Date: 09/05/2023

Nr Instances: 9

Nr Exposed: 4

Abatement Date: 10/23/2023

Gravity: 10

Report ID: 0627700

Contest Date:

Final Order: 09/29/2023

Related Event Code (REC):

Emphasis:


Penalty and Failure to Abate Event History
Type Latest Event Event Date Penalty Abatement Due Date Citation Type Failure to Abate Inspection
Penalty I: Informal Settlement 09/29/2023 $11,000.00 10/23/2023 Serious  
Penalty Z: Issued 09/05/2023 $15,625.00 10/23/2023 Serious  

Text For Citation: 01 Item/Group: 003 Hazard:

29 CFR 1910.119(d)(3)(ii): The employer did not document that equipment complies with recognized and generally accepted good engineering practices (RAGAGEP). a) On March 9, 2023, and at times prior, at the W.H. Braum facility located in Tuttle, Oklahoma, the employer did not document that the machinery room complied with the employer's chosen RAGAGEP, IIAR 2 (2014) Standard for Safe Design of Closed Circuit Ammonia Refrigeration Systems, Sections 6.2.1 and 6.2.5 when the machinery room allowed for the passage of air to an area that employees routinely occupy. b) On March 9, 2023, and at times prior, at the W.H. Braum facility located in Tuttle, Oklahoma, the employer did not document that the machine room's ventilation system design complied with the employer's chosen RAGAGEP, IIAR 2 (2014) Standard for Safe Design of Closed Circuit Ammonia Refrigeration Systems, Section 6.14.6.1 when the ventilation system design did not include the heat produced by the engine room's heat-producing equipment. c) On March 9, 2023, and at times prior, at the W.H. Braum facility located in Tuttle, Oklahoma, the employer did not document that the relief valve PSV-40041, 1"x1 1/4", Hansen H5633R, complied with the employer's chosen RAGAGEP, Hansen Technologies Bulletin K109J, 2019, Section - Service and Maintenance, when the pressure relief valve was not removed and replaced every five years. d) On March 9, 2023, and at times prior, at the W.H. Braum facility located in Tuttle, Oklahoma, the employer did not document that the relief valve PSV-45251, 1/2" x 3/4", Shank 803-LQ, complied with the employer's chosen RAGAGEP, Cyrus Shank Product catalog, Section - Safety Information when the pressure relief valve was not replaced every five years. e) On March 9, 2023, and at times prior, at the W.H. Braum facility located in Tuttle, Oklahoma, the employer did not document that the relief valve PSV-57091, 1/2" x 3/4", Shank 803-LQ, complied with the employer's chosen RAGAGEP, Cyrus Shank Product catalog, Section - Safety Information when the pressure relief valve was not replaced every five years. f) On March 9, 2023, and at times prior, at the W.H. Braum facility located in Tuttle, Oklahoma, the employer did not document that the relief valve PSV-57051, 1/2" x 3/4", Shank 803-LQ, complied with the employer's chosen RAGAGEP, Cyrus Shank Product catalog, Section - Safety Information when the pressure relief valve was not replaced every five years. These conditions exposed employees to the toxic hazards of ammonia.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close