Violation Detail
Standard Cited: 19100243 B02 Guarding of portable powered tools.
Inspection Nr: 1652730.015
Citation: 01003
Citation Type: Other
Abatement Status: Corrected During Inspection
Initial Penalty: $7,813.00
Current Penalty: $4,500.00
Issuance Date: 06/30/2023
Nr Instances: 6
Nr Exposed: 5
Abatement Date:
Gravity: 5
Report ID: 0627700
Contest Date:
Final Order: 08/21/2023
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/21/2023 | $4,500.00 | Other | ||
Penalty | Z: Issued | 06/30/2023 | $7,813.00 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.243(b)(2): Airhose and hose connections used for conducting compressed air to utilization equipment was not designed for the pressure and service to which they were subjected: On or about February 6, 2023, radiator style clamps were used to connect pneumatic lines to tools and other equipment, exposing employees to struck by hazards.