Violation Detail
Standard Cited: 19261053 B01 Ladders.
Inspection Nr: 1623050.015
Citation: 01003
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $3,315.00
Current Penalty: $3,315.00
Issuance Date: 11/17/2022
Nr Instances: 1
Nr Exposed: 2
Abatement Date:
Gravity: 5
Report ID: 0419700
Contest Date:
Final Order: 12/15/2022
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 11/17/2022 | $3,315.00 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1926.1053(b)(1):Where portable ladders were used for access to upper landing surfaces, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladders were used to gain access: a. On the backside of the home, at temporary residential new construction worksite, at 1652 Fruit Cove Woods Drive, Saint Johns, FL 32259: On or about September 19, 2022, the employer exposed employees to fall hazards, in that the 12-foot aluminum extension ladder was only raised about 6 inches above the roof.