Violation Detail
Standard Cited: 19260850 A Preparatory operations.
Inspection Nr: 1604163.015
Citation: 01003
Citation Type: Serious
Abatement Status: Not Completed - AD Discretion
Initial Penalty: $5,801.00
Current Penalty: $5,801.00
Issuance Date: 12/16/2022
Nr Instances: 1
Nr Exposed: 6
Abatement Date: 01/06/2023
Gravity: 10
Report ID: 0317000
Contest Date:
Final Order: 01/20/2023
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 12/16/2022 | $5,801.00 | 01/06/2023 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1926.850(a): An engineering survey was not performed by a competent person to determine the condition of the framing, floors and walls and the possibility of unplanned collapse of any portion of the structure prior to permitting employees to start demolition operations. a) Jobsite located at 913 N 26th St, Philadelphia PA: The employer did not ensure that a written engineering survey was conducted by a competent person, in accordance with this standard, to determine the structural integrity of a 1- and 3-story building undergoing demolition, potentially exposing employees to struck-by hazards. Condition noted on or about the 14-day period of June 8 - 22, 2022.