Violation Detail
Standard Cited: 19260451 B05 II General requirements.
Inspection Nr: 1602236.015
Citation: 01003
Citation Type: Serious
Abatement Status: Not Completed - AD Discretion
Initial Penalty: $4,144.00
Current Penalty: $4,144.00
Issuance Date: 08/17/2022
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 08/29/2022
Gravity: 5
Report ID: 0111700
Contest Date:
Final Order: 10/20/2022
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 08/17/2022 | $4,144.00 | 08/29/2022 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1926.451(b)(5)(ii): The end of a platform greater than 10 feet in length extended over its support more than 18 inches and the platform was not designed and installed so that the cantilevered portion of the platform was able to support employees without tipping, or had guardrails which blocked employee access to the cantilevered end. Jobsite, side of building 2 - On or about June 15, 2022, the approximately 24 foot long pump jack scaffold platform located approximately six feet above ground extended approximately five feet past its left support and right support and was not restrained to prevent tipping or equipped with guardrails to block employee access to the cantilevered ends.