Violation Detail
Standard Cited: 19100212 A01 General requirements for all machines.
Inspection Nr: 1564616.015
Citation: 01003
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $10,151.00
Current Penalty: $7,613.00
Issuance Date: 01/19/2022
Nr Instances: 1
Nr Exposed: 3
Abatement Date:
Gravity: 10
Report ID: 0522300
Contest Date:
Final Order: 02/14/2022
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 02/14/2022 | $7,613.00 | Serious | ||
| Penalty | Z: Issued | 01/19/2022 | $10,151.00 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about November 11, 2021, the employer did not ensure one or more methods of machine guarding were provided to protect the operator and other employees working at the machine from the hazards created by the point of operation and flying parts of dies on a hydraulic Cunningham Manufacturing Co. "C" style press, S/N 91597-214 with a 6" bore, 3" piston with ?' stroke.