Violation Detail
Standard Cited: 19100147 D The control of hazardous energy (lockout/tagout).
Inspection Nr: 1560762.015
Citation: 01003
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $14,502.00
Current Penalty: $12,400.00
Issuance Date: 02/04/2022
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): C
Gravity: 10
Report ID: 0524500
Contest Date:
Final Order: 03/01/2022
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/01/2022 | $12,400.00 | Serious | ||
Penalty | Z: Issued | 02/04/2022 | $14,502.00 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): On or about October 1, 2021, an employee was exposed to thermal burns while performing sanitation functions on the Heat Exchange on Line 35 in the Signatures Department. The employer failed to implement energy control application steps as the machine was not shut down or turned off to perform the servicing work [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.