Violation Detail
Standard Cited: 19261053 B01 Ladders.
Inspection Nr: 1558003.015
Citation: 01003
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $4,096.00
Current Penalty: $4,096.00
Issuance Date: 11/18/2021
Nr Instances: 1
Nr Exposed: 2
Abatement Date:
Gravity: 10
Report ID: 0522300
Contest Date:
Final Order: 12/15/2021
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 11/18/2021 | $4,096.00 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1926.1053(b)(1):When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. On or about October 14, 2021 at the job site located at 7785 Hills & Dales Rd NW, Massillon, Ohio 44646; during the installation of roofing material on a residential roof, the employer did not ensure portable ladders extend 3 feet above the upper landing surface.
Translate