Violation Detail
Standard Cited: 19100219 C04 I Mechanical power-transmission apparatus.
Inspection Nr: 1551176.015
Citation: 01003
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $8,287.00
Current Penalty: $6,500.00
Issuance Date: 03/02/2022
Nr Instances: 2
Nr Exposed: 10
Abatement Date: 03/28/2022
Gravity: 5
Report ID: 0627100
Contest Date:
Final Order: 03/29/2022
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/29/2022 | $6,500.00 | 03/28/2022 | Other | |
Penalty | Z: Issued | 03/02/2022 | $8,287.00 | 03/28/2022 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft: a) On or about September 2, 2021, at Glue Line 5, employees were exposed to the rotating shaft ends on the conveyors.