Violation Detail
Standard Cited: 19100217 B14 I Mechanical power presses.
Inspection Nr: 1550212.015
Citation: 01003
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $10,513.00
Current Penalty: $0.00
Issuance Date: 11/22/2021
Nr Instances: 1
Nr Exposed: 30
Abatement Date: 01/11/2022
Gravity: 10
Report ID: 0522000
Contest Date:
Final Order: 12/07/2021
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 12/07/2021 | $0.00 | 01/11/2022 | Serious | |
Penalty | Z: Issued | 11/22/2021 | $10,513.00 | 01/11/2022 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.217(b)(14)(i): Be so constructed as to automatically prevent the activation of a successive stroke if the stopping time or braking distance deteriorates to a point where the safety distance being utilized does not meet the requirements set forth in paragraph (c)(3)(iii)(e) or (c)(3)(vii)(c) of this section. The brake monitor used with the Type B gate or movable barrier device shall be installed in a manner to detect slide top-stop overrun beyond the normal limit reasonably established by the employer. (a) On or about August 26, 2021, the Federal Press #7 part revolution Serial #7-653 utilized as hand in die operation did not have a brake monitoring system.