Violation Detail
Standard Cited: 19100134 F02 Respiratory Protection.
Inspection Nr: 1545165.015
Citation: 01003
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $8,287.00
Current Penalty: $4,972.20
Issuance Date: 01/19/2022
Nr Instances: 2
Nr Exposed: 2
Abatement Date: 03/08/2022
Gravity: 5
Report ID: 0626700
Contest Date:
Final Order: 02/15/2022
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 02/15/2022 | $4,972.20 | 03/08/2022 | Serious | |
| Penalty | Z: Issued | 01/19/2022 | $8,287.00 | 03/08/2022 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.134(f)(2):The employer shall ensure that an employee using a tight-fitting facepiece respirator is fit tested prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) is used, and at least annually thereafter. a) On or about July 29, 2021, at Chemtrade Refinery Services Beaumont facility, the employer did not ensure that a repairmen/welders using face piece respirators were fit tested annually for the year 2020. b) On or about July 29, 2021, at Chemtrade Refinery Services Beaumont facility, the employer did not ensure that a repairmen/welder using the face piece respirator were fit tested annually for the year 2021.
Translate