Violation Detail
Standard Cited: 19100178 G11 Powered industrial trucks.
Inspection Nr: 1526710.015
Citation: 01003
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $4,476.00
Current Penalty: $3,580.80
Issuance Date: 09/13/2021
Nr Instances: 1
Nr Exposed: 3
Abatement Date:
Gravity: 1
Report ID: 0418100
Contest Date:
Final Order: 10/05/2021
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 10/05/2021 | $3,580.80 | Serious | ||
| Penalty | Z: Issued | 09/13/2021 | $4,476.00 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.178(g)(11): Precautions were not taken to prevent open flames, sparks, or electric arcs in battery charging area. a) Battery charging area - On or about April 22, 2021, employees were exposed to electrical and explosion hazards due to damaged cables on battery charger A79 EB1605.
Translate