Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1505481.015
Citation: 01003
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $13,653.00
Current Penalty: $15,625.00
Issuance Date: 06/03/2021
Nr Instances: 1
Nr Exposed: 6
Abatement Date: 06/25/2021
Gravity: 10
Report ID: 0523300
Contest Date: 06/23/2021
Final Order: 04/15/2024
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 04/15/2024 | $15,625.00 | 06/25/2021 | Serious | |
Penalty | C: Contested | 06/28/2021 | $13,653.00 | 06/25/2021 | Serious | |
Penalty | Z: Issued | 06/03/2021 | $13,653.00 | 06/25/2021 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed: a) On or about December 8, 2020, the employer had not conducted a periodic inspection of the energy control procedures at least annually for bucket elevator legs to ensure the procedures and the requirements of this standard were being followed. b) On or about December 8, 2020, the employer had not conducted a periodic inspection of the energy control procedures at least annually for the GSI grain dryer to ensure the procedures and the requirements of this standard were being followed.