Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1487711.015
Citation: 01003
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $12,288.00
Current Penalty: $7,500.00
Issuance Date: 02/01/2021
Nr Instances: 1
Nr Exposed: 30
Abatement Date: 03/23/2021
Gravity: 10
Report ID: 0111400
Contest Date:
Final Order: 03/17/2021
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/17/2021 | $7,500.00 | 03/23/2021 | Serious | |
Penalty | Z: Issued | 02/01/2021 | $12,288.00 | 03/23/2021 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: Plant 3: Procedures were not developed and documented for the carbon dioxide/ammonia (CO2/NH3) cascade refrigeration system used in conjunction with a Skaginn Individually Quick-Frozen (IQF) machine for shutting down, isolating, blocking, and securing machines or equipment to control hazardous energy .