Violation Detail
Standard Cited: 19260452 W07 Additional requirements applicable to specific types of scaffolds.
Inspection Nr: 1486759.015
Citation: 01003
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $13,653.00
Current Penalty: $13,653.00
Issuance Date: 01/29/2021
Nr Instances: 1
Nr Exposed: 3
Abatement Date:
Gravity: 10
Report ID: 0418200
Contest Date:
Final Order: 03/26/2021
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 01/29/2021 | $13,653.00 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1926.452(w)(7): The mobile scaffold platform extended outward beyond the base supports of the scaffold and outrigger frames or equivalent devices were not used to ensure stability: Star Metal Apartments located at 1041 Howell Mill Road NW, Atlanta, GA 30312, 8th floor: On August 4, 2020, the employer exposed employees to tip-over/fall hazards of approximately 18-feet to the lower level, in that scaffold extensions were used on a caster wheel supported scaffold which was not provided with devices such as counterweights or outrigging systems to prevent tip over or collapse of the scaffold system used to perform EIFS installations on overhead soffits.