Violation Detail
Standard Cited: 19100146 D09 Permit-required confined spaces
Inspection Nr: 1486418.015
Citation: 01003
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $9,639.00
Current Penalty: $7,711.00
Issuance Date: 09/28/2020
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 11/16/2020
Gravity: 5
Report ID: 0112000
Contest Date:
Final Order: 10/26/2020
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/26/2020 | $7,711.00 | 11/16/2020 | Serious | |
Penalty | Z: Issued | 09/28/2020 | $9,639.00 | 11/16/2020 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.146(d)(9): The employer did not develop and implement procedures for summoning rescue and emergency services, for rescuing entrants from permit spaces, for providing necessary emergency services to rescued employees, and/or for preventing unauthorized entry: Manhole, Confined Space ID 105: On, or after, June 15, 2020, entry was made into the space to determine whether or not the space contained live electrical conductors in preparation for the construction of a new building in close proximity to the manhole. At the time of the entry, the space was classified as a permit required confined space in that the hazards of the space were unknown. Once entry was made, provisions such as continuous ventilation was not provided to declassify the space to a non-permit required confined space in accordance with the Alternate Entry provisions of the Confined Space Program. Procedures had not been developed and implemented for summoning rescue and emergency services and for preventing unauthorized personnel from attempting a rescue.