Violation Detail
Standard Cited: 19100147 D02 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1484014.015
Citation: 01003
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $9,446.00
Current Penalty: $7,560.00
Issuance Date: 09/25/2020
Nr Instances: 5
Nr Exposed: 10
Abatement Date: 12/18/2020
Gravity:
Report ID: 0522300
Contest Date:
Final Order: 10/26/2020
Related Event Code (REC): A
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/26/2020 | $7,560.00 | 12/18/2020 | Other | |
Penalty | Z: Issued | 09/25/2020 | $9,446.00 | 10/15/2020 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment; On or about July 14, 2020 the employer failed to ensure that the Aida 300 ton mechanical power press was shut down in accordance with the procedures prior to the die change taking place and die maintenance being performed. Hazardous energy sources were not located and operated in a manner to isolate the hazardous energy sources, the equipment was not tested to verify isolation, and lockout devices not affixed to the isolation points.