Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1483730.015
Citation: 01003
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $9,639.00
Current Penalty: $9,639.00
Issuance Date: 08/12/2020
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 08/26/2020
Gravity: 5
Report ID: 0521400
Contest Date:
Final Order: 09/09/2020
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 08/12/2020 | $9,639.00 | 08/26/2020 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed. On or about July 13, 2020, the employer failed to perform periodic inspections of the energy control procedure for the Gallard Henning Nopak Baler machines over the past 2 years. This exposed machine operators to caught-in and amputation hazards due to lack of procedure review and employee competency. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).