Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1475785.015
Citation: 01003
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $9,446.00
Current Penalty: $4,723.00
Issuance Date: 07/20/2020
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 09/18/2020
Gravity: 10
Report ID: 0729700
Contest Date:
Final Order: 08/12/2020
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/12/2020 | $4,723.00 | 09/18/2020 | Serious | |
Penalty | Z: Issued | 07/20/2020 | $9,446.00 | 08/13/2020 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: At 4115 S. Johnson Rd, Chanute, KS in the Saw Shop, the employer had not ensured that specific energy control procedures were developed for the AKYAPAK CNC Drilling/Saw Machine, S/N ADM3-066, which contained electrical and pneumatic energy sources, exposing employees to electrical shock, amputation, caught-in, and struck by hazards