Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1456195.015
Citation: 01003
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $9,639.00
Current Penalty: $5,783.40
Issuance Date: 05/29/2020
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 06/15/2020
Gravity: 5
Report ID: 0625700
Contest Date:
Final Order: 06/22/2020
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 06/22/2020 | $5,783.40 | 06/15/2020 | Serious | |
Penalty | Z: Issued | 05/29/2020 | $9,639.00 | 06/15/2020 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o). a) On or about January 15, 2020 in the Extrusion Building, employees were utilizing a Belco Log Oven & Shear (Serial#: 32165-00) with out having a guard covering the chain driven pulley.