Violation Detail
Standard Cited: 19100147 C05 II The control of hazardous energy (lockout/tagout).
Inspection Nr: 1450126.015
Citation: 01003
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $7,210.00
Current Penalty: $5,047.00
Issuance Date: 03/18/2020
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 04/15/2020
Gravity: 5
Report ID: 0521100
Contest Date:
Final Order: 05/04/2020
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/04/2020 | $5,047.00 | 04/15/2020 | Serious | |
Penalty | Z: Issued | 03/18/2020 | $7,210.00 | 04/15/2020 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.147(c)(5)(ii): Lockout devices and tagout devices shall be singularly identified; shall be the only devices(s) used for controlling energy; shall not be used for other purposes; The Master lock on the Verson mechanical press used to keep the guard on would also be used as a lockout device when changing the cut off blade.