Violation Detail
Standard Cited: 19100147 D The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1449236.015
Citation: 01003
Citation Type: Serious
Abatement Status:
Initial Penalty: $13,494.00
Current Penalty: $0.00
Issuance Date: 04/22/2020
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 05/21/2020
Gravity: 10
Report ID: 0524500
Contest Date: 05/18/2020
Final Order: 07/14/2021
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 07/14/2021 | $0.00 | 05/21/2020 | Serious | |
Penalty | C: Contested | 06/25/2020 | $13,494.00 | 05/21/2020 | Serious | |
Penalty | Z: Issued | 04/22/2020 | $13,494.00 | 05/21/2020 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): On or about December 4, 2019, employees performing setup activities on the hydraulic Amada press brake #314 were exposed to amputation hazards and the employer failed to implement energy control application steps as the machine was not shut down to perform the setup activites [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(S)(i)J, and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.